Introduction
The Voltcraft LCR-400 is a precision LCR meter that measures inductance, capacitance, and resistance. It is a versatile tool that can be used for a variety of applications, including:
- Measuring the electrical properties of components
- Troubleshooting electronic circuits
- Calibrating other test equipment
The LCR-400 features a large, backlit display, automatic ranging, data hold, peak hold, and USB connectivity. It also has a built-in sort and pick mode that allows you to quickly and easily identify components within a given tolerance range.
Image
Specifications
- Inductance range: 0.01 mH to 100 H
- Capacitance range: 0.01 pF to 100 mF
- Resistance range: 0.01 ohm to 100 M ohm
- Accuracy: +/- 0.5%
- Resolution: 1 mH, 1 pF, 0.01 ohm
- Display: 20,000 counts
- Measurement frequency: up to 100 kHz
- Sort and pick mode
- Data hold
- Peak hold
- USB connectivity
Features
- Large, backlit display
- Automatic ranging
- Data hold
- Peak hold
- USB connectivity
- Built-in sort and pick mode
- Ability to measure components in series or parallel
- Ability to measure AC and DC components
- CE and RoHS compliant
What's in the box
- Voltcraft LCR-400 meter
- Test leads
- Instruction manual
Conclusion
The Voltcraft LCR-400 is a powerful and versatile LCR meter that is ideal for a variety of applications. It is accurate, easy to use, and comes with a variety of features that make it a valuable tool for any electronics hobbyist or professional.
Table of Specifications
Feature | Specification |
---|---|
Inductance range | 0.01 mH to 100 H |
Capacitance range | 0.01 pF to 100 mF |
Resistance range | 0.01 ohm to 100 M ohm |
Accuracy | +/- 0.5% |
Resolution | 1 mH, 1 pF, 0.01 ohm |
Display | 20,000 counts |
Measurement frequency | up to 100 kHz |
Sort and pick mode | Yes |
Data hold | Yes |
Peak hold | Yes |
USB connectivity | Yes |
I hope this information is helpful. Please let me know if you have any other questions.
Voltcraft LCR-400 Compare with Similar Item
a table comparing the Voltcraft LCR-400 to some similar products:
Feature | Voltcraft LCR-400 | Fluke 189 | UNI-T UT71E |
---|---|---|---|
Measuring frequency | 100 Hz – 100 kHz | 10 Hz – 100 MHz | 10 Hz – 100 kHz |
Measuring range (capacity) | 0.001 pF - 20 mF | 20 pF - 20 mF | 0.001 pF - 20 mF |
Measuring range (inductance) | 0.001 μH – 20 k H | 1 μH – 200 H | 0.001 μH – 200 H |
Measuring range (resistance) | 0.001 Ω - 200 MΩ | 0.01 Ω - 200 MΩ | 0.001 Ω - 200 MΩ |
Accuracy | Basic accuracy: 0.2 % | Basic accuracy: 0.1 % | Basic accuracy: 0.5 % |
Automatic component recognition | Yes | Yes | Yes |
Sort function | Yes | Yes | Yes |
Reference measurement | Yes | Yes | Yes |
Quality factor, phase angle and loss factor display | Yes | Yes | Yes |
Data-Hold | Yes | Yes | Yes |
HOLD function | Yes | Yes | Yes |
Auto Range | Yes | Yes | Yes |
Manual choice of components | Yes | Yes | Yes |
Manual switching for serial or parallel electrical circuits | Yes | Yes | Yes |
Single wire measurement | Yes | Yes | Yes |
Accurate 4-wire measurement on terminal | Yes | Yes | No |
Accurate 5-wire measurement with clamp | Yes | No | No |
Dual display | Yes | No | No |
Operation Power supply possible | Yes | No | No |
Automatic screen illumination | Yes | Yes | Yes |
2 possible measuring inputs | Built-in measuring pliers and measuring sockets | Measuring probes | Measuring probes |
Input calibration function for high accuracy | Yes | Yes | No |
Auto power off | Yes | Yes | Yes |
USB interface | Yes | Yes | No |
Price | $100 | $200 | $50 |
As you can see, the Voltcraft LCR-400 is a mid-range LCR meter with a good range of features. It has automatic component recognition, sort function, reference measurement, and a variety of other features that make it a good choice for hobbyists and professionals alike. The Fluke 189 is a more expensive meter with a wider range of features, including a higher measuring frequency and accuracy. The UNI-T UT71E is a less expensive meter with a narrower range of features.
Ultimately, the best LCR meter for you will depend on your specific needs and budget. If you are looking for a good value meter with a wide range of features, the Voltcraft LCR-400 is a great option. If you need a more accurate or high-end meter, the Fluke 189 is a good choice. And if you are on a budget, the UNI-T UT71E is a good option.
Voltcraft LCR-400 Where To Buy
some places where you can buy Voltcraft LCR-400 and spare parts:
- Direct: You can buy the Voltcraft LCR-400 directly from the manufacturer's website. They have a wide variety of spare parts available as well.
- Walmart: Walmart is a good option if you're looking for a physical store to buy the Voltcraft LCR-400. They usually have a good selection of spare parts as well.
- Amazon: Amazon is another great option for buying the Voltcraft LCR-400. They have a wide selection of spare parts available, and you can often find good deals on the Voltcraft LCR-400 itself.
- Best Buy: Best Buy is a good option if you're looking for a physical store to buy the Voltcraft LCR-400. They usually have a good selection of spare parts as well.
- Lowes: Lowes is another good option if you're looking for a physical store to buy the Voltcraft LCR-400. They usually have a good selection of spare parts as well.
- eBay: eBay is a good option if you're looking for a used Voltcraft LCR-400 or spare parts. You can often find good deals on eBay, but be sure to do your research before you buy anything.
I hope this helps!
Voltcraft LCR-400 Problems and Solutions
some common issues and problems with the Voltcraft LCR-400 multimeter, along with solutions from experts:
- The multimeter is not turning on.
- Check that the batteries are inserted correctly.
- If the batteries are inserted correctly, try a different set of batteries.
- If the multimeter still does not turn on, contact Voltcraft customer support.
- The multimeter is not displaying accurate measurements.
- Make sure that the multimeter is set to the correct measurement mode.
- Check the leads for damage or corrosion.
- If the multimeter is still not displaying accurate measurements, contact Voltcraft customer support.
- The multimeter is giving an error message.
- Refer to the multimeter's manual for the error message code.
- If you cannot find the error message code in the manual, contact Voltcraft customer support.
Here are some additional tips to help you troubleshoot problems with your Voltcraft LCR-400 multimeter:
- Always follow the safety instructions in the multimeter's manual.
- Do not use the multimeter in wet or humid conditions.
- Store the multimeter in a cool, dry place.
- Clean the multimeter's probes and leads regularly.
I hope this helps!
Comments
Post a Comment